{"title":"Split Systems","description":null,"products":[{"product_id":"yh660e2s11-jhe60d5ch2ss1-york-5-ton-16-seer2-r-454b-heat-pump-system-bundle","title":"York 5 Ton 16 SEER2 R-454B High-Efficiency Heat Pump System Bundle *SPECIAL OFFER*","description":"\u003cp\u003eThe \u003cstrong\u003eYork YH6 + JHE\u003c\/strong\u003e is a factory-matched R-454B High-Efficiency Heat Pump System; assembled as a complete, ready-to-install York Premium Bundle.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eWhat's Included in This Bundle\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRespicare Whole Home Air Purifier\u003c\/strong\u003e — whole-house indoor air quality and purification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3M Foil Tape\u003c\/strong\u003e — professional-grade sealing for ductwork and connections\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRectorseal Surge Protector \/ Voltage Monitoring Disconnect\u003c\/strong\u003e — protects the system from power surges and voltage irregularities\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHoneywell S1000 Thermostat\u003c\/strong\u003e — precise, easy-to-use temperature control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSS1 Float Switch\u003c\/strong\u003e — condensate overflow protection to help prevent water damage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e½\" x 6' Electrical Whip\u003c\/strong\u003e — pre-assembled electrical connection whip for a faster hookup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e The York YH6 Heat Pump Condenser\u003c\/strong\u003e delivers high-efficiency, year-round heating and cooling performance engineered for modern residential and light commercial HVAC applications. Featuring an advanced two-stage scroll compressor and a durable coil design, this split-system outdoor unit provides precise temperature control, enhanced indoor humidity management, and maximum seasonal efficiency rated up to 16 SEER2 and 8.0+ HSPF2. Built with low-GWP R-454B refrigerant and a heavy-gauge, salt-spray-rated steel cabinet, the YH6 Heat Pump Condenser offers an eco-friendly, long-lasting solution for total home or business climate control.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Energy Savings:\u003c\/strong\u003e Reaches up to 16 SEER2 and 8.0+ HSPF2 ratings, meeting CEE Tier 1 requirements for lower utility bills and potential tax credit eligibility.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTwo-Stage Scroll Compressor:\u003c\/strong\u003e Operates at two capacities to deliver consistent temperature control, superior dehumidification, and quieter performance compared to single-stage units.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEco-Friendly Low-GWP Refrigerant:\u003c\/strong\u003e Uses next-generation R-454B refrigerant to ensure low Global Warming Potential and full compliance with modern environmental standards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRugged Cabinet Protection:\u003c\/strong\u003e Features a heavy-gauge galvanized steel cabinet finished with a corrosion-resistant, powder-coat paint and protective coil guards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVersatile System Matching:\u003c\/strong\u003e Fully compatible with matching air handlers or gas furnaces to create high-performance heat pump systems or dual-fuel hybrid systems.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQuiet \u0026amp; Service-Friendly Design:\u003c\/strong\u003e Engineered with swept-wing fan blades for low outdoor noise levels, alongside corner service panels for fast installation and maintenance access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eSmooth sides and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588191297,"sku":"YH660E2S11 - JHE60D5CH2SS1","price":6347.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york_premium_bundle_1000_e5f1db80-dfd5-491a-af56-9063f4dd9f25.jpg?v=1790725998"},{"product_id":"hh860e2s11-jhc60c5ch2ss1-york-5-ton-19-seer2-r-454b-variable-speed-heat-pump-system-variable-speed-air-handler-21-wide","title":"York 5 Ton 19 SEER2 R-454B Variable Speed Heat Pump System (Variable Speed Air Handler) 21\" Wide","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588256833,"sku":"HH860E2S11 - JHC60C5CH2SS1","price":6335.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-4-5-ton_737484da-8326-4bc1-b5d5-96353890c237.jpg?v=1790726000"},{"product_id":"hh860e2s11-jhc48d5cg2ss1-york-4-ton-18-seer2-r-454b-variable-speed-heat-pump-system-variable-speed-air-handler-24-5-wide","title":"York 4 Ton 18 SEER2 R-454B Variable Speed Heat Pump System (Variable Speed Air Handler) 24.5\" Wide","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588289601,"sku":"HH860E2S11 - JHC48D5CG2SS1","price":6270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-4-5-ton_f904365d-66be-4a6a-8a51-2eaaa84ea601.jpg?v=1790726001"},{"product_id":"hh860e2s11-jhc48c5cg2ss1-york-4-ton-19-seer2-r-454b-variable-speed-heat-pump-system-variable-speed-air-handler-21-wide","title":"York 4 Ton 19 SEER2 R-454B Variable Speed Heat Pump System (Variable Speed Air Handler) 21\" Wide","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588322369,"sku":"HH860E2S11 - JHC48C5CG2SS1","price":6265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-4-5-ton_2dab1472-5e1c-4fed-9389-93190aec82af.jpg?v=1790726002"},{"product_id":"yh460e2s11-jhc60d5ch2ss1-york-5-ton-14-3-seer2-r-454b-variable-speed-heat-pump-system-24-5-wide","title":"York 5 Ton 14.3 SEER2 R-454B Variable Speed Heat Pump System (24.5\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588355137,"sku":"YH460E2S11 - JHC60D5CJ2SS1","price":6130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_18_3d5a0334-1bda-4e45-bdc1-6bdc7bf3e5ce.jpg?v=1790726004"},{"product_id":"yh460e2s11-jhc60c5ch2ss1-york-5-ton-14-3-seer2-r-454b-variable-speed-heat-pump-system-21-wide","title":"York 5 Ton 14.3 SEER2 R-454B Variable Speed Heat Pump System (21\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588387905,"sku":"YH460E2S11 - JHC60C5CH2SS1","price":6121.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_18_993d7d7e-c333-4a05-9a9b-f75c6c1bc531.jpg?v=1790726006"},{"product_id":"hh860e2s11-jhe60c5ch2ss1-york-5-ton-19-seer2-variable-speed-heat-pump-system-ecm-air-handler-21-wide","title":"York 5 Ton 19 SEER2 Variable Speed Heat Pump System (ECM Air Handler) 21\" Wide","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588453441,"sku":"HH860E2S11 - JHE60C5CH2SS1","price":5961.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-4-5-ton_97782844-f25b-49e4-904e-69b383efc6b1.jpg?v=1790726011"},{"product_id":"hh860e2s11-jhe48c5cg2ss1-york-4-ton-19-seer2-variable-speed-heat-pump-system-ecm-air-handler-21-wide","title":"York 4 Ton 19 SEER2 Variable Speed Heat Pump System (ECM Air Handler) 21\" Wide","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588486209,"sku":"HH860E2S11 - JHE48C5CG2SS1","price":5891.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-4-5-ton.jpg?v=1790726013"},{"product_id":"yh448e2s11-jhc48d5cg2ss1-york-4-ton-14-3-seer2-r-454b-variable-speed-heat-pump-system-24-5-wide","title":"York 4 Ton 14.3 SEER2 R-454B Variable Speed Heat Pump System (24.5\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588518977,"sku":"YH448E2S11 - JHC48D5CG2SS1","price":5871.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_17_46cfb655-3eed-4181-88bd-59296b3c40c4.jpg?v=1790726014"},{"product_id":"yh448e2s11-jhc48c5cg2ss1-york-4-ton-14-3-seer2-r-454b-variable-speed-heat-pump-system-21-wide","title":"York 4 Ton 14.3 SEER2 R-454B Variable Speed Heat Pump System (21\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588551745,"sku":"YH448E2S11 - JHC48C5CG2SS1","price":5866.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_17_b90850fd-8df0-4d67-a7b7-297479029b8f.jpg?v=1790726016"},{"product_id":"yh648e2s11-jhe60d5ch2ss1-york-4-ton-16-seer2-r-454b-heat-pump-system-bundle","title":"York 4 Ton 16 SEER2 R-454B High-Efficiency Heat Pump System Bundle *SPECIAL OFFER*","description":"\u003cp\u003eThe \u003cstrong\u003eYork YH6 + JHE\u003c\/strong\u003e is a factory-matched R-454B High-Efficiency Heat Pump System; assembled as a complete, ready-to-install York Premium Bundle.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eWhat's Included in This Bundle\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRespicare Whole Home Air Purifier\u003c\/strong\u003e — whole-house indoor air quality and purification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3M Foil Tape\u003c\/strong\u003e — professional-grade sealing for ductwork and connections\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRectorseal Surge Protector \/ Voltage Monitoring Disconnect\u003c\/strong\u003e — protects the system from power surges and voltage irregularities\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHoneywell S1000 Thermostat\u003c\/strong\u003e — precise, easy-to-use temperature control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSS1 Float Switch\u003c\/strong\u003e — condensate overflow protection to help prevent water damage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e½\" x 6' Electrical Whip\u003c\/strong\u003e — pre-assembled electrical connection whip for a faster hookup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e The York YH6 Heat Pump Condenser\u003c\/strong\u003e delivers high-efficiency, year-round heating and cooling performance engineered for modern residential and light commercial HVAC applications. Featuring an advanced two-stage scroll compressor and a durable coil design, this split-system outdoor unit provides precise temperature control, enhanced indoor humidity management, and maximum seasonal efficiency rated up to 16 SEER2 and 8.0+ HSPF2. Built with low-GWP R-454B refrigerant and a heavy-gauge, salt-spray-rated steel cabinet, the YH6 Heat Pump Condenser offers an eco-friendly, long-lasting solution for total home or business climate control.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Energy Savings:\u003c\/strong\u003e Reaches up to 16 SEER2 and 8.0+ HSPF2 ratings, meeting CEE Tier 1 requirements for lower utility bills and potential tax credit eligibility.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTwo-Stage Scroll Compressor:\u003c\/strong\u003e Operates at two capacities to deliver consistent temperature control, superior dehumidification, and quieter performance compared to single-stage units.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEco-Friendly Low-GWP Refrigerant:\u003c\/strong\u003e Uses next-generation R-454B refrigerant to ensure low Global Warming Potential and full compliance with modern environmental standards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRugged Cabinet Protection:\u003c\/strong\u003e Features a heavy-gauge galvanized steel cabinet finished with a corrosion-resistant, powder-coat paint and protective coil guards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVersatile System Matching:\u003c\/strong\u003e Fully compatible with matching air handlers or gas furnaces to create high-performance heat pump systems or dual-fuel hybrid systems.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQuiet \u0026amp; Service-Friendly Design:\u003c\/strong\u003e Engineered with swept-wing fan blades for low outdoor noise levels, alongside corner service panels for fast installation and maintenance access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eSmooth sides and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588584513,"sku":"YH648E2S11 - JHE60D5CH2SS1","price":5820.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york_premium_bundle_1000_89131373-fe5e-4e8f-be43-7ec4da0d00bb.jpg?v=1790726017"},{"product_id":"yh460e2s11-jhe60d5ch2ss1-york-5-ton-14-3-seer2-r-454b-heat-pump-system-24-5-wide","title":"York 5 Ton 14.3 SEER2 R-454B Heat Pump System (24.5\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588617281,"sku":"YH460E2S11 - JHE60D5CH2SS1","price":5806.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_18_6e2be9ad-0f9e-495e-936b-5142b2e825d1.jpg?v=1790726019"},{"product_id":"yc460e2s11-jhc60d5ch2ss1-york-5-ton-14-5-seer2-r-454b-variable-speed-air-conditioning-system-24-5-wide","title":"York 5 Ton 14.5 SEER2 R-454B Variable Speed Air Conditioning System (24.5\" Wide)","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588650049,"sku":"YC460E2S11 - JHC60D5CJ2SS1","price":5777.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_13_aafa9579-1f41-461f-bdab-6dfaa6387a38.jpg?v=1790726020"},{"product_id":"yc460e2s11-jhc60c5ch2ss1-york-5-ton-14-5-seer2-r-454b-variable-speed-air-conditioning-system-21-wide","title":"York 5 Ton 14.5 SEER2 R-454B Variable Speed Air Conditioning System (21\" Wide)","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588682817,"sku":"YC460E2S11 - JHC60C5CH2SS1","price":5766.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_13_c7eecbf6-e710-4ed1-95e2-f590655ef386.jpg?v=1790726022"},{"product_id":"yh460e2s11-jhe60c5ch2ss1-york-5-ton-14-3-seer2-r-454b-heat-pump-system-21-wide","title":"York 5 Ton 14.3 SEER2 R-454B Heat Pump System (21\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588715585,"sku":"YH460E2S11 - JHE60C5CH2SS1","price":5746.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_18.jpg?v=1790726023"},{"product_id":"yh448e2s11-jhe48c5cg2ss1-york-4-ton-14-3-seer2-r-454b-heat-pump-system-21-wide","title":"York 4 Ton 14.3 SEER2 R-454B Heat Pump System (21\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588748353,"sku":"YH448E2S11 - JHE48C5CG2SS1","price":5702.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_17.jpg?v=1790726024"},{"product_id":"hh836e2s11-jhc36c5cd2ss1-york-3-ton-19-seer2-r-454b-variable-speed-heat-pump-system-variable-speed-air-handler-21-wide","title":"York 3 Ton 19 SEER2 R-454B Variable Speed Heat Pump System (Variable Speed Air Handler) 21\" Wide","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588813889,"sku":"HH836E2S11 - JHC36C5AD2SS1","price":5626.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-2-3-ton_1_cdfd853e-962d-47e9-ab5a-65b66b93a7a3.jpg?v=1790726025"},{"product_id":"hh836e2s11-jhc36b5cd2ss1-york-3-ton-19-seer2-r-454b-variable-speed-heat-pump-system-variable-speed-air-handler-17-5-wide","title":"York 3 Ton 19 SEER2 R-454B Variable Speed Heat Pump System (Variable Speed Air Handler) 17.5\" Wide","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588846657,"sku":"HH836E2S11 - JHC36B5AD2SS1","price":5597.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-2-3-ton_1_81161074-b0af-4c34-8064-5109a61f3bcb.jpg?v=1790726027"},{"product_id":"yc460e2s11-jhe60d5ch2ss1-york-5-ton-14-5-seer2-r-454b-air-conditioning-system-24-5-wide","title":"York 5 Ton 14.5 SEER2 R-454B Air Conditioning System (24.5\" Wide)","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588879425,"sku":"YC460E2S11 - JHE60D5CH2SS1","price":5452.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_13_e7b48758-f08c-4687-adeb-0ef0f13fec29.jpg?v=1790726029"},{"product_id":"yh560e2s11-jhc60d5ch2ss1-york-5-ton-15-2-seer2-r-454b-variable-speed-heat-pump-system-24-5-wide","title":"York 5 Ton 15.2 SEER2 R-454B Variable Speed Heat Pump System (24.5\" Wide)","description":"\u003cp\u003eThe York YH5 Heat Pump is part of our successful split system heat pump lineup. These outdoor units are optimized for 15.2 SEER2\/7.8 HSPF2 Minimum Efficiency in all US Regions, and are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588912193,"sku":"YH560E2S11 - JHC60D5CJ2SS1","price":5407.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_22_9833bf76-d7a8-40d3-914c-34f5848f90d2.jpg?v=1790726030"},{"product_id":"yh560e2s11-jhc60c5ch2ss1-york-5-ton-15-2-seer2-r-454b-variable-speed-heat-pump-system-21-wide","title":"York 5 Ton 15.2 SEER2 R-454B Variable Speed Heat Pump System (21\" Wide)","description":"\u003cp\u003eThe York YH5 Heat Pump is part of our successful split system heat pump lineup. These outdoor units are optimized for 15.2 SEER2\/7.8 HSPF2 Minimum Efficiency in all US Regions, and are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588944961,"sku":"YH560E2S11 - JHC60C5CH2SS1","price":5397.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_22_3f3e862e-f960-43b9-8534-61de09f067d5.jpg?v=1790726032"},{"product_id":"yc448e2s11-jhc48c5cg2ss1-york-4-ton-15-seer2-r-454b-variable-speed-air-conditioning-system-21-wide","title":"York 4 Ton 15 SEER2 R-454B Variable Speed Air Conditioning System (21\" Wide)","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577588977729,"sku":"YC448E2S11 - JHC48C5CG2SS1","price":5397.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_12_c85e8dac-5831-4b5d-b83c-84c424c5c1c9.jpg?v=1790726033"},{"product_id":"yc460e2s11-jhe60c5ch2ss1-york-5-ton-14-25-seer2-r-454b-air-conditioning-system-21-wide","title":"York 5 Ton 14.25 SEER2 R-454B Air Conditioning System (21\" Wide)","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589010497,"sku":"YC460E2S11 - JHE60C5CH2SS1","price":5392.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_13.jpg?v=1790726035"},{"product_id":"yc660e2s11-jhe60c5ch2ss1-york-5-ton-16-seer2-r-454b-air-conditioning-system-bundle","title":"York 5 Ton 16 SEER2 R-454B High-Efficiency Air Conditioning System Bundle *SPECIAL OFFER*","description":"\u003cp\u003eThe \u003cstrong\u003eYork YC6 + JHE\u003c\/strong\u003e is a factory-matched R-454B High-Efficiency Air Conditioning System; assembled as a complete, ready-to-install York Premium Bundle.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eWhat's Included in This Bundle\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRespicare Whole Home Air Purifier\u003c\/strong\u003e — whole-house indoor air quality and purification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3M Foil Tape\u003c\/strong\u003e — professional-grade sealing for ductwork and connections\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRectorseal Surge Protector \/ Voltage Monitoring Disconnect\u003c\/strong\u003e — protects the system from power surges and voltage irregularities\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHoneywell S1000 Thermostat\u003c\/strong\u003e — precise, easy-to-use temperature control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSS1 Float Switch\u003c\/strong\u003e — condensate overflow protection to help prevent water damage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e½\" x 6' Electrical Whip\u003c\/strong\u003e — pre-assembled electrical connection whip for a faster hookup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e The York YC6 Condenser\u003c\/strong\u003e delivers powerful, high-efficiency cooling performance designed for reliable residential and light commercial applications. Engineered with a durable single-stage scroll compressor and an optimized coil system, this split-system air conditioner condenser offers quiet operation, low energy consumption, and dependable seasonal cooling efficiency rated up to 16+ SEER2. Built with heavy-duty cabinet protection to withstand severe weather elements, the YC6 is an exceptional replacement or new-system choice for dependable summer comfort.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling:\u003c\/strong\u003e Delivers energy-conscious performance up to 16+ SEER2 to keep utility bills low during peak summer months.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReliable Scroll Compressor:\u003c\/strong\u003e Equipped with a heavy-duty single-stage scroll compressor designed for continuous operation, quiet performance, and longevity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDurable Cabinet Design:\u003c\/strong\u003e Features heavy-gauge powder-coated galvanized steel construction and protective coil guards to defend against weather and impact damage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOptimized Heat Transfer:\u003c\/strong\u003e Utilizes advanced coil technology to maximize heat dissipation and system efficiency.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmentally Mindful:\u003c\/strong\u003e Uses eco-friendly R-454B refrigerant for efficient and safe system operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eService-Friendly Layout:\u003c\/strong\u003e Easy-access control valves and corner service panels allow for straightforward installation and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cbr\u003e\u003cbr\u003e\n\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eSmooth sides and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589076033,"sku":"YC660E2S11 - JHE60C5CH2SS1","price":5274.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york_premium_bundle_1000_113effae-2e1b-49ea-af25-79f061de2866.jpg?v=1790726036"},{"product_id":"hh836e2s11-jhe36c5cd2ss1-york-3-ton-19-seer2-r-454b-variable-speed-heat-pump-system-ecm-air-handler-21-wide","title":"York 3 Ton 19 SEER2 R-454B Variable Speed Heat Pump System (ECM Air Handler) 21\" Wide","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589108801,"sku":"HH836E2S11 - JHE36C5AD2SS1","price":5258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-2-3-ton_1_8245a588-6ca4-49e6-ab74-9b23b76abe17.jpg?v=1790726037"},{"product_id":"hh836e2s11-jhe36b5cd2ss1-york-3-ton-19-seer2-r-454b-variable-speed-heat-pump-system-ecm-air-handler-17-5-wide","title":"York 3 Ton 19 SEER2 R-454B Variable Speed Heat Pump System (ECM Air Handler) 17.5\" Wide","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589141569,"sku":"HH836E2S11 - JHE36B5CD2SS1","price":5227.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-2-3-ton_1.jpg?v=1790726039"},{"product_id":"yh436e2s11-jhc36c5cd2ss1-york-3-ton-14-3-seer2-r-454b-variable-speed-heat-pump-system-21-wide","title":"York 3 Ton 14.3 SEER2 R-454B Variable Speed Heat Pump System (21\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589174337,"sku":"YH436E2S11 - JHC36C5AD2SS1","price":5203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_16_bb25781e-1838-41e2-9f9d-b79d571a8312.jpg?v=1790726040"},{"product_id":"yh436e2s11-jhc36b5cd2ss1-york-3-ton-14-3-seer2-r-454b-variable-speed-heat-pump-system-17-5-wide","title":"York 3 Ton 14.3 SEER2 R-454B Variable Speed Heat Pump System (17.5\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589207105,"sku":"YH436E2S11 - JHC36B5AD2SS1","price":5173.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_16_938f86ad-2363-4f85-a8e4-206569a7ea94.jpg?v=1790726042"},{"product_id":"yh636e2s11-jhe36c5cd2ss1-york-3-ton-16-seer2-r-454b-heat-pump-system-bundle","title":"York 3 Ton 16 SEER2 R-454B High-Efficiency Heat Pump System Bundle *SPECIAL OFFER*","description":"\u003cp\u003eThe \u003cstrong\u003eYork YH6 + JHE\u003c\/strong\u003e is a factory-matched R-454B High-Efficiency Heat Pump System; assembled as a complete, ready-to-install York Premium Bundle.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eWhat's Included in This Bundle\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRespicare Whole Home Air Purifier\u003c\/strong\u003e — whole-house indoor air quality and purification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3M Foil Tape\u003c\/strong\u003e — professional-grade sealing for ductwork and connections\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRectorseal Surge Protector \/ Voltage Monitoring Disconnect\u003c\/strong\u003e — protects the system from power surges and voltage irregularities\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHoneywell S1000 Thermostat\u003c\/strong\u003e — precise, easy-to-use temperature control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSS1 Float Switch\u003c\/strong\u003e — condensate overflow protection to help prevent water damage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e½\" x 6' Electrical Whip\u003c\/strong\u003e — pre-assembled electrical connection whip for a faster hookup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e The York YH6 Heat Pump Condenser\u003c\/strong\u003e delivers high-efficiency, year-round heating and cooling performance engineered for modern residential and light commercial HVAC applications. Featuring an advanced two-stage scroll compressor and a durable coil design, this split-system outdoor unit provides precise temperature control, enhanced indoor humidity management, and maximum seasonal efficiency rated up to 16 SEER2 and 8.0+ HSPF2. Built with low-GWP R-454B refrigerant and a heavy-gauge, salt-spray-rated steel cabinet, the YH6 Heat Pump Condenser offers an eco-friendly, long-lasting solution for total home or business climate control.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Energy Savings:\u003c\/strong\u003e Reaches up to 16 SEER2 and 8.0+ HSPF2 ratings, meeting CEE Tier 1 requirements for lower utility bills and potential tax credit eligibility.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTwo-Stage Scroll Compressor:\u003c\/strong\u003e Operates at two capacities to deliver consistent temperature control, superior dehumidification, and quieter performance compared to single-stage units.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEco-Friendly Low-GWP Refrigerant:\u003c\/strong\u003e Uses next-generation R-454B refrigerant to ensure low Global Warming Potential and full compliance with modern environmental standards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRugged Cabinet Protection:\u003c\/strong\u003e Features a heavy-gauge galvanized steel cabinet finished with a corrosion-resistant, powder-coat paint and protective coil guards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVersatile System Matching:\u003c\/strong\u003e Fully compatible with matching air handlers or gas furnaces to create high-performance heat pump systems or dual-fuel hybrid systems.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQuiet \u0026amp; Service-Friendly Design:\u003c\/strong\u003e Engineered with swept-wing fan blades for low outdoor noise levels, alongside corner service panels for fast installation and maintenance access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eSmooth sides and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589239873,"sku":"YH636E2S11 - JHE36C5CD2SS1","price":5095.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york_premium_bundle_1000_5f17645a-8a14-4d23-b1fc-ac83e1418f64.jpg?v=1790726043"},{"product_id":"yh560e2s11-jhe60d5ch2ss1-york-5-ton-15-2-seer2-r-454b-heat-pump-system","title":"York 5 Ton 15.2 SEER2 R-454B Heat Pump System","description":"\u003cp\u003eThe York YH5 Heat Pump is part of our successful split system heat pump lineup. These outdoor units are optimized for 15.2 SEER2\/7.8 HSPF2 Minimum Efficiency in all US Regions, and are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589272641,"sku":"YH560E2S11 - JHE60D5CH2SS1","price":5084.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_22.jpg?v=1790726045"},{"product_id":"yc448e2s11-jhe48c5cg2ss1-york-4-ton-14-25-seer2-r-454b-air-conditioning-system","title":"York 4 Ton 14.25 SEER2 R-454B Air Conditioning System","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589305409,"sku":"YC448E2S11 - JHE48C5CG2SS1","price":5024.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_12.jpg?v=1790726046"},{"product_id":"yc648e2s11-jhe60c5ch2ss1-york-4-ton-17-seer2-r-454b-air-conditioning-system-bundle","title":"York 4 Ton 17 SEER2 R-454B High-Efficiency Air Conditioning System Bundle *SPECIAL OFFER*","description":"\u003cp\u003eThe \u003cstrong\u003eYork YC6 + JHE\u003c\/strong\u003e is a factory-matched R-454B High-Efficiency Air Conditioning System; assembled as a complete, ready-to-install York Premium Bundle.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eWhat's Included in This Bundle\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRespicare Whole Home Air Purifier\u003c\/strong\u003e — whole-house indoor air quality and purification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3M Foil Tape\u003c\/strong\u003e — professional-grade sealing for ductwork and connections\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRectorseal Surge Protector \/ Voltage Monitoring Disconnect\u003c\/strong\u003e — protects the system from power surges and voltage irregularities\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHoneywell S1000 Thermostat\u003c\/strong\u003e — precise, easy-to-use temperature control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSS1 Float Switch\u003c\/strong\u003e — condensate overflow protection to help prevent water damage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e½\" x 6' Electrical Whip\u003c\/strong\u003e — pre-assembled electrical connection whip for a faster hookup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e The York YC6 Condenser\u003c\/strong\u003e delivers powerful, high-efficiency cooling performance designed for reliable residential and light commercial applications. Engineered with a durable single-stage scroll compressor and an optimized coil system, this split-system air conditioner condenser offers quiet operation, low energy consumption, and dependable seasonal cooling efficiency rated up to 16+ SEER2. Built with heavy-duty cabinet protection to withstand severe weather elements, the YC6 is an exceptional replacement or new-system choice for dependable summer comfort.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling:\u003c\/strong\u003e Delivers energy-conscious performance up to 16+ SEER2 to keep utility bills low during peak summer months.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReliable Scroll Compressor:\u003c\/strong\u003e Equipped with a heavy-duty single-stage scroll compressor designed for continuous operation, quiet performance, and longevity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDurable Cabinet Design:\u003c\/strong\u003e Features heavy-gauge powder-coated galvanized steel construction and protective coil guards to defend against weather and impact damage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOptimized Heat Transfer:\u003c\/strong\u003e Utilizes advanced coil technology to maximize heat dissipation and system efficiency.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmentally Mindful:\u003c\/strong\u003e Uses eco-friendly R-454B refrigerant for efficient and safe system operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eService-Friendly Layout:\u003c\/strong\u003e Easy-access control valves and corner service panels allow for straightforward installation and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cbr\u003e\u003cbr\u003e\n\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eSmooth sides and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589403713,"sku":"YC648E2S11 - JHE60C5CH2SS1","price":5047.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york_premium_bundle_1000_15ad9b3c-644e-4651-827c-2fab2a1e74d0.jpg?v=1790726048"},{"product_id":"yc442e2s11-jhc42d5cf2ss1-york-3-5-ton-15-5-seer2-r-454b-variable-speed-air-conditioning-system-24-5-wide","title":"York 3.5 Ton 15.5 SEER2 R-454B Variable Speed Air Conditioning System (24.5\" Wide)","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589436481,"sku":"YC442E2S11 - JHC42D5CF2SS1","price":5004.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_11_65707d83-345f-4e32-a8d4-b31eb866a7c9.jpg?v=1790726049"},{"product_id":"yh548e2s11-jhc48d5cg2ss1-york-4-ton-15-2-seer2-r-454b-variable-speed-heat-pump-system-24-5-wide","title":"York 4 Ton 15.2 SEER2 R-454B Variable Speed Heat Pump System (24.5\" Wide)","description":"\u003cp\u003eThe York YH5 Heat Pump is part of our successful split system heat pump lineup. These outdoor units are optimized for 15.2 SEER2\/7.8 HSPF2 Minimum Efficiency in all US Regions, and are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589534785,"sku":"YH548E2S11 - JHC48D5CG2SS1","price":4998.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_21_c69b6759-e43b-43ea-a633-990e8a1623fd.jpg?v=1790726051"},{"product_id":"yh548e2s11-jhc48c5cg2ss1-york-4-ton-15-2-seer2-r-454b-variable-speed-heat-pump-system-21-wide","title":"York 4 Ton 15.2 SEER2 R-454B Variable Speed Heat Pump System (21\" Wide)","description":"\u003cp\u003eThe York YH5 Heat Pump is part of our successful split system heat pump lineup. These outdoor units are optimized for 15.2 SEER2\/7.8 HSPF2 Minimum Efficiency in all US Regions, and are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589600321,"sku":"YH548E2S11 - JHC48C5CG2SS1","price":4993.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_21_7e840482-2d4e-4cea-9c24-aa5ba89a4a41.jpg?v=1790726052"},{"product_id":"yc442e2s11-jhc42c5cf2ss1-york-3-5-ton-15-5-seer2-r-454b-variable-speed-air-conditioning-system-21-wide","title":"York 3.5 Ton 15.5 SEER2 R-454B Variable Speed Air Conditioning System (21\" Wide)","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589633089,"sku":"YC442E2S11 - JHC42C5CF2SS1","price":4993.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_11_d73f3fc8-9a5d-4ac3-b380-0b33f5dfd2dd.jpg?v=1790726054"},{"product_id":"hh824e2s11-jhc24b5ac2ss1-york-2-ton-19-seer2-r-454b-variable-speed-heat-pump-system-variable-speed-air-handler","title":"York 2 Ton 19 SEER2 R-454B Variable Speed Heat Pump System (Variable Speed Air Handler)","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589665857,"sku":"HH824E2S11 - JHC24B5AC2SS1","price":4948.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-2-3-ton_02ea46b3-2940-41d8-b5e5-fae904b23a04.jpg?v=1790726055"},{"product_id":"yh436e2s11-jhe36c5cd2ss1-york-3-ton-14-3-seer2-r-454b-heat-pump-system-21-wide","title":"York 3 Ton 14.3 SEER2 R-454B Heat Pump System (21\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589731393,"sku":"YH436E2S11 - JHE36C5AD2SS1","price":4834.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_16_1e26093e-8384-4185-88d0-3490de25f877.jpg?v=1790726057"},{"product_id":"yc460e2s11-ctm60d5chs1-york-5-ton-13-8-seer2-r-454b-r-32-air-conditioning-condenser-and-horizontal-coil-24-5-high","title":"York 5 Ton 13.8 SEER2 R-454B R-32 Air Conditioning Condenser and Horizontal Coil (24.5\" High)","description":"\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York CT Cased Coils are specially designed for installation with our residential furnaces or modular air handlers as part of a matched air conditioning or heat pump system.\u003c\/p\u003e\n\u003cp\u003eOur residential indoor coils can be applied with indoor thermostatic expansion valves (TXVs) according to the application. Most indoor coil models are available as flex coils for installation of the specific expansion device in the field. Select SKUs are available with factory mounted TXVs. Refer to the Technical Guide for the matched outdoor unit to determine the required indoor expansion device for your specific application.\u003c\/p\u003e\n\u003cp\u003eCTF series full-cased coils are suitable for upflow or downflow applications. CTM series full-cased multi-position coils are designed for horizontal left, horizontal right, upflow, or downflow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe rigid case construction provides structural support and eliminates screw heads protruding from the side of the cabinet that could damage property during installation. \u003c\/li\u003e\n\u003cli\u003eThe cabinet is constructed of heavy gauge galvanized steel with a primer and finish coat that provides a high-quality corrosion resistant finish. \u003c\/li\u003e\n\u003cli\u003eMaxAlloy™ coil: These long-life aluminum coils are built to deliver lasting performance, efficiency, and reliability. \u003c\/li\u003e\n\u003cli\u003eFoil-faced insulation: The cabinet is insulated with a single piece of cleanable foil-faced insulation. The cabinet is designed so that all edges of the insulation are contained. \u003c\/li\u003e\n\u003cli\u003eCompact cabinet: With the coil and access doors removed, the cabinet has a 20.5 in. casing depth in all models, allowing ease of access in attics and applications where space is constrained.\u003c\/li\u003e\n\u003cli\u003eThermoset drain pan: The drain pan is corrosion and UV resistant with a positive slope for proper drainage. The low water retention design maximizes indoor air quality and consumer comfort. \u003c\/li\u003e\n\u003cli\u003eLow leakage cabinet design: Fully gasketed doors minimize air leakage to no more than 2% when measured at 1.0 in. W.C. external static pressure, minimizing conditioned air leakage and infiltration. \u003c\/li\u003e\n\u003cli\u003eDuct flange: An integral duct flange is part of the coil casing for easy installation. \u003c\/li\u003e\n\u003cli\u003eTXV: Select factory-installed and field-installed models are available. They use Chatleff fittings, and no brazing is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589764161,"sku":"YC460E2S11 - CTM60D5CHS1","price":4834.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-cu-hori-coil-split_6_4baa26ee-c4c4-4760-b20a-6420b93163fd.jpg?v=1790726058"},{"product_id":"yc460e2s11-ctm60c5chs1-york-5-ton-13-8-seer2-r-454b-r-32-air-conditioning-condenser-and-horizontal-coil-21-high","title":"York 5 Ton 13.8 SEER2 R-454B R-32 Air Conditioning Condenser and Horizontal Coil (21\" High)","description":"\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York CT Cased Coils are specially designed for installation with our residential furnaces or modular air handlers as part of a matched air conditioning or heat pump system.\u003c\/p\u003e\n\u003cp\u003eOur residential indoor coils can be applied with indoor thermostatic expansion valves (TXVs) according to the application. Most indoor coil models are available as flex coils for installation of the specific expansion device in the field. Select SKUs are available with factory mounted TXVs. Refer to the Technical Guide for the matched outdoor unit to determine the required indoor expansion device for your specific application.\u003c\/p\u003e\n\u003cp\u003eCTF series full-cased coils are suitable for upflow or downflow applications. CTM series full-cased multi-position coils are designed for horizontal left, horizontal right, upflow, or downflow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe rigid case construction provides structural support and eliminates screw heads protruding from the side of the cabinet that could damage property during installation. \u003c\/li\u003e\n\u003cli\u003eThe cabinet is constructed of heavy gauge galvanized steel with a primer and finish coat that provides a high-quality corrosion resistant finish. \u003c\/li\u003e\n\u003cli\u003eMaxAlloy™ coil: These long-life aluminum coils are built to deliver lasting performance, efficiency, and reliability. \u003c\/li\u003e\n\u003cli\u003eFoil-faced insulation: The cabinet is insulated with a single piece of cleanable foil-faced insulation. The cabinet is designed so that all edges of the insulation are contained. \u003c\/li\u003e\n\u003cli\u003eCompact cabinet: With the coil and access doors removed, the cabinet has a 20.5 in. casing depth in all models, allowing ease of access in attics and applications where space is constrained.\u003c\/li\u003e\n\u003cli\u003eThermoset drain pan: The drain pan is corrosion and UV resistant with a positive slope for proper drainage. The low water retention design maximizes indoor air quality and consumer comfort. \u003c\/li\u003e\n\u003cli\u003eLow leakage cabinet design: Fully gasketed doors minimize air leakage to no more than 2% when measured at 1.0 in. W.C. external static pressure, minimizing conditioned air leakage and infiltration. \u003c\/li\u003e\n\u003cli\u003eDuct flange: An integral duct flange is part of the coil casing for easy installation. \u003c\/li\u003e\n\u003cli\u003eTXV: Select factory-installed and field-installed models are available. They use Chatleff fittings, and no brazing is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589796929,"sku":"YC460E2S11 - CTM60C5CHS1","price":4808.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-cu-hori-coil-split_6.jpg?v=1790726060"},{"product_id":"yh436e2s11-jhe36b5cd2ss1-york-3-ton-14-3-seer2-r-454b-heat-pump-system-17-5-wide","title":"York 3 Ton 14.3 SEER2 R-454B Heat Pump System (17.5\" Wide)","description":"\u003cp\u003eThe York YH4 Heat Pump is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589862465,"sku":"YH436E2S11 - JHE36B5CD2SS1","price":4804.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_16.jpg?v=1790726061"},{"product_id":"yc436e2s11-jhc36c5cd2ss1-york-3-ton-15-5-seer2-r-454b-variable-speed-air-conditioning-system","title":"York 3 Ton 15.5 SEER2 R-454B Variable Speed Air Conditioning System","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589928001,"sku":"YC436E2S11 -  JHC36B5AD2SS1","price":4704.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_10_62e2e72b-c6ef-47fe-a961-7137d32f65b6.jpg?v=1790726062"},{"product_id":"yc436e2s11-jhc36b5cd2ss1-york-3-ton-15-seer2-r-454b-variable-speed-air-conditioning-system","title":"York 3 Ton 15 SEER2 R-454B Variable Speed Air Conditioning System","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589960769,"sku":"YC436E2S11 - JHC36B5CD2SS1","price":4704.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_10_5910cd2a-de9f-4983-b89d-8520f7dad405.jpg?v=1790726064"},{"product_id":"yc460e2s11-ctf60d5chs1-york-5-ton-13-8-seer2-r-454b-r-32-air-conditioning-condenser-and-coil-24-5-wide","title":"York 5 Ton 13.8 SEER2 R-454B R-32 Air Conditioning Condenser and Coil (24.5\" Wide)","description":"\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York CT Cased Coils are specially designed for installation with our residential furnaces or modular air handlers as part of a matched air conditioning or heat pump system.\u003c\/p\u003e\n\u003cp\u003eOur residential indoor coils can be applied with indoor thermostatic expansion valves (TXVs) according to the application. Most indoor coil models are available as flex coils for installation of the specific expansion device in the field. Select SKUs are available with factory mounted TXVs. Refer to the Technical Guide for the matched outdoor unit to determine the required indoor expansion device for your specific application.\u003c\/p\u003e\n\u003cp\u003eCTF series full-cased coils are suitable for upflow or downflow applications. CTM series full-cased multi-position coils are designed for horizontal left, horizontal right, upflow, or downflow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe rigid case construction provides structural support and eliminates screw heads protruding from the side of the cabinet that could damage property during installation. \u003c\/li\u003e\n\u003cli\u003eThe cabinet is constructed of heavy gauge galvanized steel with a primer and finish coat that provides a high-quality corrosion resistant finish. \u003c\/li\u003e\n\u003cli\u003eMaxAlloy™ coil: These long-life aluminum coils are built to deliver lasting performance, efficiency, and reliability. \u003c\/li\u003e\n\u003cli\u003eFoil-faced insulation: The cabinet is insulated with a single piece of cleanable foil-faced insulation. The cabinet is designed so that all edges of the insulation are contained. \u003c\/li\u003e\n\u003cli\u003eCompact cabinet: With the coil and access doors removed, the cabinet has a 20.5 in. casing depth in all models, allowing ease of access in attics and applications where space is constrained.\u003c\/li\u003e\n\u003cli\u003eThermoset drain pan: The drain pan is corrosion and UV resistant with a positive slope for proper drainage. The low water retention design maximizes indoor air quality and consumer comfort. \u003c\/li\u003e\n\u003cli\u003eLow leakage cabinet design: Fully gasketed doors minimize air leakage to no more than 2% when measured at 1.0 in. W.C. external static pressure, minimizing conditioned air leakage and infiltration. \u003c\/li\u003e\n\u003cli\u003eDuct flange: An integral duct flange is part of the coil casing for easy installation. \u003c\/li\u003e\n\u003cli\u003eTXV: Select factory-installed and field-installed models are available. They use Chatleff fittings, and no brazing is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577589993537,"sku":"YC460E2S11 - CTF60D5CHS1","price":4679.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-cu-vert-coil-split_6_b2964395-217d-4deb-9f33-966b7fdd7d46.jpg?v=1790726065"},{"product_id":"yc442e2s11-jhe42c5cf2ss1-york-3-5-ton-15-seer2-r-454b-air-conditioning-system","title":"York 3.5 Ton 15 SEER2 R-454B Air Conditioning System","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577590026305,"sku":"YC442E2S11 - JHE42C5CF2SS1","price":4649.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_11.jpg?v=1790726067"},{"product_id":"yc460e2s11-ctf60c5chs1-york-5-ton-13-8-seer2-r-454b-r-32-air-conditioning-condenser-and-coil-21-wide","title":"York 5 Ton 13.8 SEER2 R-454B R-32 Air Conditioning Condenser and Coil (21\" Wide)","description":"\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York CT Cased Coils are specially designed for installation with our residential furnaces or modular air handlers as part of a matched air conditioning or heat pump system.\u003c\/p\u003e\n\u003cp\u003eOur residential indoor coils can be applied with indoor thermostatic expansion valves (TXVs) according to the application. Most indoor coil models are available as flex coils for installation of the specific expansion device in the field. Select SKUs are available with factory mounted TXVs. Refer to the Technical Guide for the matched outdoor unit to determine the required indoor expansion device for your specific application.\u003c\/p\u003e\n\u003cp\u003eCTF series full-cased coils are suitable for upflow or downflow applications. CTM series full-cased multi-position coils are designed for horizontal left, horizontal right, upflow, or downflow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe rigid case construction provides structural support and eliminates screw heads protruding from the side of the cabinet that could damage property during installation. \u003c\/li\u003e\n\u003cli\u003eThe cabinet is constructed of heavy gauge galvanized steel with a primer and finish coat that provides a high-quality corrosion resistant finish. \u003c\/li\u003e\n\u003cli\u003eMaxAlloy™ coil: These long-life aluminum coils are built to deliver lasting performance, efficiency, and reliability. \u003c\/li\u003e\n\u003cli\u003eFoil-faced insulation: The cabinet is insulated with a single piece of cleanable foil-faced insulation. The cabinet is designed so that all edges of the insulation are contained. \u003c\/li\u003e\n\u003cli\u003eCompact cabinet: With the coil and access doors removed, the cabinet has a 20.5 in. casing depth in all models, allowing ease of access in attics and applications where space is constrained.\u003c\/li\u003e\n\u003cli\u003eThermoset drain pan: The drain pan is corrosion and UV resistant with a positive slope for proper drainage. The low water retention design maximizes indoor air quality and consumer comfort. \u003c\/li\u003e\n\u003cli\u003eLow leakage cabinet design: Fully gasketed doors minimize air leakage to no more than 2% when measured at 1.0 in. W.C. external static pressure, minimizing conditioned air leakage and infiltration. \u003c\/li\u003e\n\u003cli\u003eDuct flange: An integral duct flange is part of the coil casing for easy installation. \u003c\/li\u003e\n\u003cli\u003eTXV: Select factory-installed and field-installed models are available. They use Chatleff fittings, and no brazing is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577590059073,"sku":"YC460E2S11 - CTF60C5CHS1","price":4634.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-cu-vert-coil-split_6.jpg?v=1790726068"},{"product_id":"yh548e2s11-jhe48c5cg2ss1-york-4-ton-15-2-seer2-r-454b-heat-pump-system-21-wide","title":"York 4 Ton 15.2 SEER2 R-454B Heat Pump System (21\" Wide)","description":"\u003cp\u003eThe York YH5 Heat Pump is part of our successful split system heat pump lineup. These outdoor units are optimized for 15.2 SEER2\/7.8 HSPF2 Minimum Efficiency in all US Regions, and are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577590124609,"sku":"YH548E2S11 - JHE48C5CG2SS1","price":4619.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_21.jpg?v=1790726069"},{"product_id":"yh536e2s11-jhc36c5cd2ss1-york-3-ton-15-2-seer2-r-454b-variable-speed-heat-pump-system-21-wide","title":"York 3 Ton 15.2 SEER2 R-454B Variable Speed Heat Pump System (21\" Wide)","description":"\u003cp\u003eThe York YH5 Heat Pump is part of our successful split system heat pump lineup. These outdoor units are optimized for 15.2 SEER2\/7.8 HSPF2 Minimum Efficiency in all US Regions, and are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577590190145,"sku":"YH536E2S11 - JHC36C5AD2SS1","price":4580.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_20_8c7036bd-08b0-4717-96a9-401fd72e9388.jpg?v=1790726071"},{"product_id":"yc430e2s11-jhc36c5ad2ss1-york-2-5-ton-15-75-seer2-r-454b-variable-speed-air-conditioning-system","title":"York 2.5 Ton 15.75 SEER2 R-454B Variable Speed Air Conditioning System","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:  When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online \u003ca href=\"https:\/\/www.floridabuilding.org\/fbc\/thecode\/2023_Code_Development\/2023_Code_Resources\/BLDG-124_DBPR_Energy_Code_Changes_Brochure_2023.pdf\"\u003ehere\u003c\/a\u003e or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003eThe York YC4 Air Conditioner is part of our successful 14.3 SEER2 Regional Minimum Efficiency product line available in the United States. These outdoor units are specifically designed to be matched with our residential indoor coils, furnaces, and air handlers to provide a complete system solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint - Minimum footprint for easier handling, transportation, and installation. \u003c\/li\u003e\n\u003cli\u003eEasier installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factory-charged for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier retrofits. \u003c\/li\u003e\n\u003cli\u003eAccessible information - QR code on unit provides quick access to technical documents and warranty information. \u003c\/li\u003e\n\u003cli\u003eDurable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint further protects external panels. \u003c\/li\u003e\n\u003cli\u003eQuality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system, providing reliable performance and small unit size. \u003c\/li\u003e\n\u003cli\u003eRugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. \u003c\/li\u003e\n\u003cli\u003eProtected compressor - Compressors are protected internally by a high-pressure relief valve and a temperature sensor, and externally by the system high-pressure switch. \u003c\/li\u003e\n\u003cli\u003eReliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. \u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with zero ozone depletion. \u003c\/li\u003e\n\u003cli\u003eTop discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location on multi-unit applications. \u003c\/li\u003e\n\u003cli\u003eLow operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available. \u003c\/li\u003e\n\u003cli\u003eBetter service access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. \u003c\/li\u003e\n\u003cli\u003eAgency listed - Safety certified by CSA to UL 60335-2-40\/CSA C22.2. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577590517825,"sku":"YC430E2S11 - JHC36C5AD2SS1","price":4565.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-split-electric_9_60b6ecf3-0ea8-41e4-b486-81e97ba5acca.jpg?v=1790726072"},{"product_id":"hh824e2s11-jhe24b5ac2ss1-york-2-ton-19-seer2-r-454b-variable-speed-heat-pump-system-ecm-air-handler","title":"York 2 Ton 19 SEER2 R-454B Variable Speed Heat Pump System (ECM Air Handler)","description":"\u003cp\u003eThe York HH8 horizontal discharge variable speed heat pumps are the outdoor section of a high-efficiency heating and cooling system. The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Match each HH8 unit with one ducted indoor unit. This unit is not designed for application in a ductless configuration. Sweat connect units are factory charged with refrigerant for a nominal sized matching indoor coil plus 15 ft of field-supplied lines.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e360 DC inverter driven technology: With 360 DC inverter driven technology, compressor rotation direction and speed is controlled, optimizing energy usage and compressor stability through the range of operating conditions. This guarantees optimal space temperature control while providing quiet operation. \u003c\/li\u003e\n\u003cli\u003ePressure sensor: This unit contains pressure sensing technology, which detects low pressure in cooling mode and high pressure in heating mode to protect the system from damage. Intelligent control can also be achieved by calculating the indoor coil temperature from system suction pressure. \u003c\/li\u003e\n\u003cli\u003eSmaller outdoor form factor for installation flexibility: This side-discharge outdoor unit saves roughly 35% space over traditional air conditioners. It offers the flexibility of wall, yard, or roof installation. \u003c\/li\u003e\n\u003cli\u003eStable temperature control means optimal comfort: The DC inverter is able to provide full capacity at startup to cool or warm quickly and adjusts speed to prevent temperature fluctuation and energy loss. \u003c\/li\u003e\n\u003cli\u003eAgency listed: Safety certified by UL 60335-2-40:2022 Ed.4 and CSA C22.2#60335-2-40:2022 Ed.4. Performance certified to ANSI\/AHRI Standard 210\/240 in accordance with the Unitary Small Equipment certification program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"acstore","offers":[{"title":"Default Title","offer_id":50577590878273,"sku":"HH824E2S11 - JHE24B5AC2SS1","price":4545.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/7575\/3025\/files\/york-hh8-split-electric-2-3-ton.jpg?v=1790726074"}],"url":"https:\/\/acwholesalecentre.com\/collections\/split-systems.oembed","provider":"acwholesalecentre","version":"1.0","type":"link"}